Line regulation: ±0.3% max.
Load regulation: – Single output models: ±0.5% max.
– Dual output models: ±0.5% max.
Ripple & Noise: <75 mVpk-pk (20 MHz BW)
Conducted EMI: EN 55022, class A and FCC, level A (internal filter)
Short circuit protection: continuous, automatic recovery
Efficiency: 82% typ. 3.3 VDC models: 76% typ.
Operating temperature range: –40°C … +85°C above 70°C derating 4%/°C
I/O isolation voltage: 1500 VDC
Safety standards: cUL/UL 60950, IEC/EN 60950
Case: metal, with insulated baseplate
www.powersolve.co.uk
Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
Order Code Input voltage Output voltage Output current
max.
TEN 5-2410WI 3.3 VDC 1200 mA
TEN 5-2411WI 5 VDC 1000 mA
TEN 5-2412WI 12 VDC 500 mA
TEN 5-2413WI 9 – 36 VDC 15 VDC 400 mA
TEN 5-2421WI ±5 VDC ±500 mA
TEN 5-2422WI ±12 VDC ±250 mA
TEN 5-2423WI ±15 VDC ±200 mA
TEN 5-4810WI 3.3 VDC 1200 mA
TEN 5-4811WI 5 VDC 1000 mA
TEN 5-4812WI
12
VDC
500 mA
TEN 5-4813WI
18 – 75 VDC
15
VDC
400
mA
TEN 5-4821WI ±5 VDC ±500 mA
TEN 5-4822WI
±
12 VDC
±250 mA
TEN 5-4823WI
±
15 VDC
±
200
mA
= DIL-24 Metal Package
= Ultrawide 4:1 Input Range
= High Efficiency up to 84%
= Operating Temperature Range –40°C to +85°C
= I/O Isolation 1500 VDC
= Short Circuit Protection
=
Input Filter to meet EN 55022, Class A
= Industry Standard Pinout
= Reflow solder temperature up to 250°C
DC/DC Converters
TEN 5WI Series, 6 Watt
Models
Pin Single Output Dual Output
2 – Vin (GND) – Vin (GND)
3 – Vin (GND) – Vin (GND)
9 No pin Common
11 No con. – Vout
14 + Vout + Vout
16
– V
out
Common
22 + Vin (Vcc) + Vin (Vcc)
23 + Vin (Vcc) + Vin (Vcc)
Pin-Out
22.86
20.3
4.5
32
10.2
5
15.24
11
9
22
23
2
3
14
16
Bottom view
2.54
15.24
2.4
5.08
(0.6)
(0.8)
(0.1)
(0.4)
(0.2)
(1.25)
(0.9)
(0.18)
(0.1)
(0.2)
(0.6)
Insulated Baseplate