Powersolve CFM40T Series User Manual

Browse online or download User Manual for Power suppliers Powersolve CFM40T Series. Powersolve CFM40T Series User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converters
CFM40D/T Series
40 Watt Dual/Triple Output
Features
Universal Input : 90 ~ 264Vac
2”x 4” Footprint
Industry-Standard Pin Out
Efficiency at 75% Typical (70% for CFM40T-07)
Meets UL/cUL,TUV,CE
Conductive EMI Meets CISPR/FCC Class B
INPUT
Input voltage 90 - 264 VAC
Input frequency 47 to 63 Hz
Inrush Current 50A max. @ 264Vac
Input Current 1A max. (RMS) @ 115Vac
Conducted EMI CISPR/FCC Class B
Isolation Input to output = 4,242Vdc
Leakage Current 3.5mA max.
OUTPUT
Rated Power for Convection Cooling 40W (CFM40T-07, 30W)
Maximum Power with 30 CFM Forced Air 50W (CFM40T-07, 40W)
Hold-up T
ime
20mS typ. @115V
ac
Short Circuit/ Over Load Protection On All Outputs (Auto Recovery)
Over Voltage Protection 3.6~4.6V/5.7~6.7V ON V1(3.3V/5V)
120%~140% ON V2(12V/15V/24V)
Adjustment Range +10% typ.
ENVIRONMENTAL
Operating Temperature 0 ~ 45°C
Storage Temperature -20 ~ 85°C
MECHANICAL CHARACTERISTICS
Dimensions
101.6 x 50.8 x 30.48 mm
Electrical Specification
T
ypical @ 25
°
C, nominal line and 75% load, unless other
wise specified
®